High vacuum relief regulator operation, Shut-down, 3 shut-down – AEC VacTrac Series Conveying Systems User Manual

Page 85

Advertising
background image

High Vacuum Relief Regulator Operation
A factory-set pressure regulator is installed on the pump package vent valve as a mechanical
back-up safety feature. It protects the pump motor from damage during high vacuum
conditions if an undetected failure of the vacuum switch should occur. The regulator is set to
limit system vacuum to 15” Hg (475 millibars) by allowing the vent valve plunger to shift
and vent the pump.

Note: Do

not adjust the pressure regulator. Adjusting the pressure regulator voids

your warranty.

See Figure 40 on page 74 for additional operation information.

4-3 Shut-down

To deactivate the conveying system:

1. Turn the disconnect switch at each pump or component to OFF. This will take each

pump or component offline.

2. Turn off the compressed air supply to the system.

Note: Consult your specific controller operation and instruction manual for specific

shut-down information for your conveying system.

Conveying System Mechanical Components Chapter 4: Operation