$PAMTC,COMP,RESETALL

Summary

Reset the user calibration coefficients and damping control to the default values.

Syntax

$PAMTC,COMP,RESETALL*hh<CR><LF>


Reply

The weather station will reset the user calibration coefficients and damping

control (fields 1-9) and reply with:
$PAMTR,COMP,RESETALL,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh<CR><LF>
where fields <1> through <9> contain the data from the weather station’s

nonvolatile EEPROM, as defined in the “Q”, Query Command.

$PAMTC,COMP,RESETCAL

Summary

Reset the user calibration coefficients to the default values.

Syntax

$PAMTC,COMP,RESETCAL*hh<CR><LF>

Reply

The weather station will reset the user calibration coefficients (fields 1 – 6) and

reply with:
$PAMTR,COMP,RESETCAL,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh<CR><LF>
where fields <1> through <9> contain the data from the weather station’s

nonvolatile EEPROM, as defined in the “Q”, Query Command.

$PAMTC,COMP,RESETDAMP

Summary

Reset the user damping control to the default values.

Syntax

$PAMTC,COMP,RESETDAMP*hh<CR><LF>

Reply

The weather station will reset the user damping control (fields 7-9) and reply

with:
$PAMTR,COMP,RESETDAMP,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh<CR><LF>