NMEA 0183 RECEIVED SENTENCE

_

$PAMTC,

EN

Summary

Enable or disable the periodic transmission of individual standard NMEA 0183

sentences, and specify their rate of transmission.

Syntax

One of the following forms:
$PAMTC,EN,<2>,<3>,<4>*hh<CR><LF>

$PAMTC,EN,S*hh<CR><LF>

$PAMTC,EN,L*hh<CR><LF>

$PAMTC,EN,LD*hh<CR><LF>

$PAMTC,EN,Q*hh<CR><LF>

Fields

<2>

The identifier ALL, or one of the following sentence ID’s:

DTM, GGA, GLL, GSA, GSV, HDG, HDT, MDA,

MWD, MWVR, MWVT, RMC, ROT, VTG, VWR, VWT,
XDRA, XDRB, ZDA

<3>

If field <2> is the ALL identifier, then

0 = disable transmission of all sentences

1 = enable transmission of all sentences.

Otherwise,

0 = disable transmission of the specified sentence

1 = enable transmission of the specified sentence

<4>

The amount of time between successive transmissions of the specified

sentence, in tenths of a second. For example, if field <4> contains the

value 5, this specifies an interval of 0.5 seconds between successive

transmissions of the specified sentence.
If field <2> is the ALL identifier, then field <4> specifies the

transmission interval for all sentences.