LB150 WeatherStation Technical Manual revision 0.013

Proprietary and Confidential

PRELIMINARY - DRAFT

56

_

NMEA 0183 RECEIVED SENTENCE

_

$PAMTC,

HEATER

Summary

Control the internal heater within the weather station.

Syntax

One of the following forms:


$PAMTC,HEATER,0*hh<CR><LF>

Turn heater off (default state).

$PAMTC,HEATER,A*hh<CR><LF>

Control heater automatically.

$PAMTC,HEATER,Q*hh<CR><LF>

Query heater status, and start

reporting subsequent changes in

status

$PAMTC,HEATER,X*hh<CR><LF>

Stop reporting heater status change

Notes

The heater may be used in the weather station to prevent the formation of dew or

ice on the aluminum plate in the wind channel. If the heater control is set to "A"

(automatic control), then the weather station will automatically cycle the heater on

and off over time to keep the plate temperature within appropriate limits based on

the air temperature (and dew point temperature, if product has humidity sensor,

PBxxx products do not, LBxxx products do).
If a $PAMTC,HEATER,Q (Query) command is received, then every time the

heater status changes, the sensor will transmit the following message:

$PAMTR,HEATER,<1>,<2>,<3>*hh<CR><LF>

where

<1>

= Heater mode (M = manual, A = automatic)

<2>

= Heater state (0 = heater Off, 1 = heater On)

<2>

= Heater control (V = Valid, if Factory enabled, else NULL)

Heater status change reporting may be disabled with the $PAMTC,HEATER,X

command.
Note that when the heater is on, the air temperature sensor within the unit will be

heated by the heater and will not provide an accurate indication of outside

ambient air temperature.
This is a factory enabled option that is not present by default.

Advertising