Erst, Pamtc – Airmar LB150 User Manual

Page 58

Advertising
background image

LB150 WeatherStation Technical Manual revision 0.013

Proprietary and Confidential

PRELIMINARY - DRAFT

55

_

NMEA 0183 RECEIVED SENTENCE

_

$PAMTC,

ERST

Summary

Reset the user portion of nonvolatile EEPROM to its factory default state.

Syntax

$PAMTC,ERST*hh<CR><LF>

Notes

The following data items are saved in nonvolatile EEPROM within the LB150

WeatherStation. For each item, the default value, and the command used to

change the value is shown.

Item

Default value

Changed via command

Azimuth offset

0.0°

$PAMTC,ATTOFF

Pitch offset

0.0°

$PAMTC,ATTOFF

Roll offset

0.0°

$PAMTC,ATTOFF

List of sentences

enabled for transmission

See the description for the

$PAMTC,EN command

$PAMTC,EN

Rates of transmission of

sentences

See the description for the

$PAMTC,EN command

$PAMTC,EN

Allow COG to be used

instead of internal

compass heading in true

wind calculations

Disabled

$PAMTC,OPTION

GPS fix 2D, 3D, or Auto

Auto

$PAMTC,OPTION

Altitude settings

0,1,2

$PAMTC,ALT


Other items related to factory calibration of the sensor are also saved in

EEPROM, but these items are not affected by the $PAMTC,ERST command.