Initial Installation

Before connecting the DC power to the transceiver, be sure to switch



the transceiver and the DC power supply OFF.
Do not plug the DC power supply into an AC outlet until you make all



connections.

In order to use this transceiver for fixed station operation, you will need

a separate 13.8V DC power supply (not included) , Please contact local

dealer to require.
The current capacity of your power supply must be 12A or more.

Connect the DC power cable to the regulated DC power supply

1.

and ensure that the polarities are correct. (Red: positive, Black:

negative).

Never directly connect the transceiver to an AC outlet.



Use the supplied DC power cable to connect the transceiver to a



regulated power supply.
Do not substitute a cable with smaller gauge wires.



Connect the transceiver's DC power connector to the connector

2.

on

the DC power cable.

Press the connectors firmly together until the locking tab clicks



.

Red

Black

DC power cable with fuse holder

Regulated

power supply

Fixed Station Operation

Ext. Power jack

ACC terminal

Cigar-Plug connection

Optional EDC-43 required

REPLACING FUSES

If the fuse blows,determine the cause, then correct the problem. After the

problem is resolved, replace the fuse. If newly installed fuses continue to

blow, disconnect the power cable and contact your dealer for assistance.

Only use fuses of the specified type and rating, otherwise the transceiver

could be damaged.

Fuse Location

Fuse Current Rating

Transceiver

15A

Supplied Accessory DC

power cable

20A

If you use the transceiver for a long period when the vehicle battery is
not fully charged, or when the engine is OFF, the battery may become
discharged, and will not have sufficient reserves to start the vehicle. Avoid
using the transceiver in these conditions.