REPLACING CONVECTION BLOWER

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper operation after servicing

.

This

appliance, when installed, must be electrically grounded in accordance with local codes or, in
the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical code, CSA C22.1.

NOTES:

Make sure the gas to the appliance has been shut off.

Ensure that the main power and breaker system is turned off before removing the fan.

Make sure the fireplace has been turned off and is cool to the touch.

Mark all wires to be removed for proper reassembly.

CAUTION: Wiring errors cause improper and dangerous operation.
If any of the original wire supplied with the appliance must be replaced, it must be replaced with
type 18 awg 600v 105 C wire, or its equivalent.

1. Remove the glass door. Follow GLASS DOOR REMOVAL instructions within this manual.
2. Remove the log set. Follow LOG PLACEMENT instructions within this manual.
3. Loosen the adjustment wing nut and slide the air shutter to the left. Follow ADJUSTING

PRIMARY AIR instructions within this manual.

4. Remove the pan burner. Follow instructions for CHANGING MAIN BURNER ORIFICE within

this manual.

5. Remove valve tray assembly. Make sure to test for gas leaks at every fitting removed to

access the fan assembly when re-assembling.

6. Mark all wires to be removed for proper reassembly.
7. The convection blower is located at the bottom of the appliance at the back. Remove the

three screws holding the blower.

8. Lift the blower out and disconnect the wires from the blower.
9. Reverse these steps after new fan is installed & tested.

To Appliance Body

120 VAC

white

black

SPEED

CONTROL

LINE

GROUND

NEUTRAL

110ºF (43ºC) N.O.

THERMAL SNAP

SWITCH

CONVECTION BLOWER

black

white

black

green

WIRING DIAGRAM

MO

SPEED

CONTROL

110F (43ºC) N.O.

THERMAL SNAP

SWITCH

CONVECTION BLOWER

LINE

GROUND

NEUTRAL