Eneo HDD-2030PTZ1080 User Manual

Page 16

Advertising
background image

6. Select “START ANGLE”. Hold down the CTRL key while selecting the start position using the

Joystick. Current panning position will be displayed. Release the CTRL key to complete the

selection of the start position. Or press the IRIS Open key then the “CONTROL” displays. Move
the desired position and the zoom position. Press the IRIS Close key then the “CONTROL”
disappears. To adjust at the 0.1 degree interval, twist the Joystick at the pan field and the tilt
field.

7. Select “END ANGLE”. Hold down the CTRL key while moving the Joystick to select the end

position. The end position angle should be larger than start position. Release the CTRL key to
complete the selection of the end position. Or press the IRIS Open key then the “CONTROL”
displays. Move the desired position and the zoom position. Press the IRIS Close key then the
“CONTROL” disappears. To adjust at the 0.1 degree interval, twist the Joystick at the pan field
and the tilt field.

8. Set “SCAN DIR” to CCW or CW.

9. Select “SWAP”, Set to ON to exchange the start angle and the end angle.

10. Set “DWELL time”.

11. Select “SAVE AND EXIT” and push the Joystick to the right or press the IRIS Open key.

Press the ESC or IRIS Close key to exit the program without saving.

NOTE: Pressing the HOME key delete stored data at the angle field.

To set the position using the Preset position:

a. Before entering the Auto Scan menu, select a Preset position as a starting point for Auto Scan.

Example: 2 + PRST keys and do step 1 to 5. In step 6, just press the CTRL key at the start

angle position, the current position will be displayed as a start position.

b. Save and Exit from the menu.

c. In normal mode, call a Preset to be the end point of Scan. Press 3 + PRST keys then press the

SCAN key to enter the Auto Scan menu. Move the cursor position to END ANGLE. Just press

the CTRL key at the end angle position. Save and exit from the menu.

Press the SCAN key on the angle field to display with the small OSD. Then the screen will show
as below.

AUTO SCAN AREA SETUP

(CTRL KEY)




NUMBER 01
START : ----- -----

END : ----- -----

EXIT(ESC TO EXIT)

The setting procedure is the same as above.

NOTE: 09: AUTO-PAN mode (endless panning)

11

Advertising
This manual is related to the following products: