3.12 Alarm

ALARM SETUP

(CTRL KEY)

NO PRI FUN IN OUT HLD LATCH
1 1 001 NO OUT1 03 OFF

2 1 --- OFF OFF 03 OFF
3 1 --- OFF OFF 03 OFF
4 1 --- OFF OFF 03 OFF

DWELL : 03 SEC
ALARM OUT SETUP

SAVE AND EXIT(ESC TO CANCEL)

NO (Number)

alarm input number

PRI (Priority)

the lower number has higher priority (0 ~ 4)

FUN (Function)

Stored function number to be called by alarm.

IN (Input)

NO/NC – normally open/closed, OFF – ignore

OUT (Output)

OUT1 ~ OUT2 – 5VTTL output, OFF – no output

HLD (Hold)

Alarm will be held for programmed time. (03 to 99 seconds)

LATCH ON – Alarm message will remain on the screen even though alarm input is

deactivated.

OFF – Alarm message will disappear from the screen after programmed

hold time when alarm input is deactivated.

DWELL

means the dwell time during multiple alarms, 03 to 99 seconds.

ALARM OUT SETUP

OUT1 : ALARM
OUT2 : 1 MIN
EXIT(ESC TO EXIT)

ALARM: alarm output is operated during an alarm operation or by the short key of our

keyboard.

1 ~ 5 MIN (minute): alarm output is operated during this setting time only by the function run

of the dome menu or the short key of our keyboard.

NOTE: This 1 ~ 5 MIN setting is not operated by an alarm.

There are 5 levels of priority. The function can be selected by Preset, Auto scan, Pattern or Tour
and “0” is the highest priority. Lower priority alarms won’t be serviced until the higher priority
alarm is completed. Equal priority alarms will be serviced repeatedly with the dwell time.