Examining the installation site

The switch can only be used indoors. To make sure the switch operates correctly and prolong its service
lifetime, the installation site must meet the requirements for load-bearing, temperature, humidity,

cleanness, EMI, grounding power module, ventilation, and space. For more information, see H3C

S10500 Switch Series Installation Guide.
If you are to install the switch in an enclosed rack, make sure the rack meets the following requirements:

A minimum of 100 mm (3.94 in) distance between the front rack posts and the front door for
accommodating the cable management brackets.

A minimum of 710 mm (27.95 in) distance between the front rack posts and the rear door for
accommodating the chassis and card handles.

Installing the switch

Attaching the slide rails to the rack

1.

Read the signs on the slide rails to identify the left and right slide rails and their front ends, as

shown in

Table 3

.

Table 3 Description for signs on the slide rails

Sign

Meaning

Remarks

F/L

Front end of the left slide rail

Mount this end to the front left rack post.

F/R

Front end of the right slide rail

Mount this end to the front right rack post.

2.

Mark the installation position on the rack for the slide rails:

a.

Make sure the top flange of a slide rail aligns with the middle of the narrower metal area
between holes in a rack post, as shown in

Figure 4

.

b.

Each rack post requires six screws to attach the slide rail. Mark only the uppermost and
lowermost holes.

c.

Mark the square holes at the same height on the other three rack posts.