# Use the display patch information command to check whether the cards have been patched and view

patch running status.

NOTE:

If a card has been patched, you must uninstall the previous patch before you can install the new patch
package.

<Sysname> display patch information

The location of patches: flash:

Slot Version Temporary Common Current Active Running Start-Address

----------------------------------------------------------------------

0 MPU001 0 1 1 0 1 0x86d97d90

0.1 MPO001 0 1 1 0 1 0x80a7b5dc

1 MPU001 0 1 1 0 1 0x86d97d90

1.1 MPO001 0 1 1 0 1 0x80a7b5dc

2 LPU001 0 1 1 0 1 0x856d5b88

2.1 LPO001 0 1 1 0 1 0x80a7b5dc

3 LPU001 0 1 1 0 1 0x856d5b88

3.1 LPO001 0 1 1 0 1 0x80a7b5dc

4 LPU001 0 1 1 0 1 0x856d5b88

4.1 LPO001 0 1 1 0 1 0x80a7b5dc

5 LPU001 0 1 1 0 1 0x856d5b88

5.1 LPO001 0 1 1 0 1 0x80a7b5dc

6 LPU001 0 1 1 0 1 0x856d5b88

The output shows that each card has a running patch. Use the undo patch install command to uninstall
the patch.
# Uninstall the patch.

<Sysname> system-view

[Sysname] undo patch install

Patches will be uninstalled. Continue? [Y/N]:y

# Check whether the uninstallation is successful.

[Sysname] display patch information

The location of patches: flash:

Slot Version Temporary Common Current Active Running Start-Address

----------------------------------------------------------------------

0 MPU 0 0 0 0 0 0x86d97d90

0.1 MPO 0 0 0 0 0 0x80a7b5dc

1 MPU 0 0 0 0 0 0x86d97d90

1.1 MPO 0 0 0 0 0 0x80a7b5dc

2 LPU 0 0 0 0 0 0x856d5b88

2.1 LPO 0 0 0 0 0 0x80a7b5dc

3 LPU 0 0 0 0 0 0x856d5b88

3.1 LPO 0 0 0 0 0 0x80a7b5dc

4 LPU 0 0 0 0 0 0x856d5b88

4.1 LPO 0 0 0 0 0 0x80a7b5dc

5 LPU 0 0 0 0 0 0x856d5b88

5.1 LPO 0 0 0 0 0 0x80a7b5dc

6 LPU 0 0 0 0 0 0x856d5b88