Network requirements – H3C Technologies H3C S7500E Series Switches User Manual

Page 62

Advertising
background image

3-27

[SwitchD-rip-1] network 11.0.0.0

[SwitchD-rip-1] version 2

[SwitchD-rip-1] undo summary

[SwitchD-rip-1] quit

# Configure RIP to redistribute the routes from OSPF process 1 and direct routes on Switch C.

[SwitchC-rip-1] import-route direct

[SwitchC-rip-1] import-route ospf 1

# Display the routing table information of Switch D.

[SwitchD] display ip routing-table

Routing Tables: Public

Destinations : 10 Routes : 10

Destination/Mask Proto Pre Cost NextHop Interface

10.1.1.0/24 RIP 100 1 11.3.1.1 Vlan300

10.2.1.0/24 RIP 100 1 11.3.1.1 Vlan300

10.5.1.0/24 RIP 100 1 11.3.1.1 Vlan300

10.6.1.0/24 RIP 100 1 11.3.1.1 Vlan300

11.3.1.0/24 Direct 0 0 11.3.1.2 Vlan300

11.3.1.2/32 Direct 0 0 127.0.0.1 InLoop0

11.4.1.0/24 Direct 0 0 11.4.1.2 Vlan400

11.4.1.2/32 Direct 0 0 127.0.0.1 InLoop0

127.0.0.0/8 Direct 0 0 127.0.0.1 InLoop0

127.0.0.1/32 Direct 0 0 127.0.0.1 InLoop0

4) Configure route summarization on Switch C and advertise only the summary route 10.0.0.0/8.

[SwitchC] interface vlan-interface 300

[SwitchC-Vlan-interface300] rip summary-address 10.0.0.0 8

# Display the routing table information of Switch D.

[SwitchD] display ip routing-table

Routing Tables: Public

Destinations : 7 Routes : 7

Destination/Mask Proto Pre Cost NextHop Interface

10.0.0.0/8 RIP 100 1 11.3.1.1 Vlan300

11.3.1.0/24 Direct 0 0 11.3.1.2 Vlan300

11.3.1.2/32 Direct 0 0 127.0.0.1 InLoop0

11.4.1.0/24 Direct 0 0 11.4.1.2 Vlan400

11.4.1.2/32 Direct 0 0 127.0.0.1 InLoop0

127.0.0.0/8 Direct 0 0 127.0.0.1 InLoop0

127.0.0.1/32 Direct 0 0 127.0.0.1 InLoop0

Configuring BFD for RIP (Single-Hop Detection in BFD Echo Packet Mode)

Network requirements

As shown in the following figure:

z

Switch A and Switch C are interconnected through a Layer 2 switch. VLAN-interface 100 of the

two switches runs RIP process 1, BFD is enabled on VLAN-interface 100 of Switch A.

Advertising