Figure 53, Tion, Table 52 – H3C Technologies H3C SecCenter IPS Manager User Manual

Page 60

Advertising
background image

54

Figure 53 Alarming configuration

Table 52 Alarming configuration items

Item Description

Alarm Mode

Optional
The following alarm modes are available:

Alarm by Email. If you select this mode, specify the email addresses and alarm time.

Alarm by SMS message: If you select this mode, specify the message receivers and
alarm time.

Alarm by sound. If you select this mode, the alarm time is optional.

Collaborate with IPS devices: If you select this mode, specify the IPS devices to
collaborate with. The attack sources will be added to the IPS blacklists to filter traffic
with these source IP addresses. Separate the IP addresses with commas.

Collaborate with firewall devices: If you select this mode, specify the firewall devices
to collaborate with. The attack sources will be added to the firewall blacklists to filter

traffic with these source IP addresses. Separate the IP addresses with commas.

Alarm Type

An alarm type is defined by any combination of Attack, Virus, DDoS, and Filter.
If you specify no alarm type (leaving the Attack, Virus, and DDoS options unselected),
the system will not raise alarms.

Advertising