Grass Valley 8920ADC v.2.0.1A User Manual

Page 27

Advertising
background image

8920ADC Instruction Manual

27

Configuration

Slot Config Web Page

Use the Slot Config web page (

Figure 12 on page 28

) to perform the fol-

lowing functions on the 8920ADC module:

Locate Module

– selecting the

Flash

radio button flashes the yellow

COMM and CONF LEDs on the front of the module so it can be located
in the frame.

Controls

– the Controls status report will display either

Normal

or

Remote

Override

if a setting on the web pages is overriding that of the module

jumpers.

Slot Identification

– You may identify the module by typing a specific

name in the

Name

field. The assigned name is stored on the 8900NET

module and travels with the 8900NET module if it is moved to another
frame. Select

Default

to enter the factory default module name.

You may also enter a name in the

Input Signal Name

field.

Slot Memory

– the slot configuration for each media module is automati-

cally saved periodically (once an hour) to the 8900NET module in that
frame. You may also select the

Learn Module Config

button at any time to

save the current configuration for this slot. The configuration is saved
on the 8900NET module. If the 8900NET module is removed or
powered down, the stored configurations are not saved.

When the

Restore upon Install

box has been checked, the current configu-

ration saved to this slot is saved as slot memory. When the current
module is removed and another module of the same type is installed,
the configuration saved to the 8900NET module will be downloaded to
the new module. The box must be checked before the current module
with the saved configuration is removed.

Frame Heath Reporting

– this function is not active with the latest version

of the 8900NET module that controls this page.

Hardware Switch Controls

– a read-only status report of 8900NET module

switch settings for Module Status Reporting and Asynchronous Status
Reporting. These functions must be enabled for the following Slot
SNMP Trap Reports to function.

Slot SNMP Trap Reports

– displayed only when the SNMP Agent software

has been installed on the 8900NET module. Slot SNMP traps can be
enabled only when the hardware switches for Module Fault reporting
and Asynchronous Status reporting are in enabled on the 8900NET
module (dipswitch S1 segment 5 and dipswitch S2 segment 1).

The enabled SNMP traps will be reported to any SNMP manager that
is identified as an SNMP Report Destination in 8900NET configuration.
Trap severity is read-only hard-coded information that is interpreted
and responded to by the SNMP Manager software configuration.

Use
this
link

Advertising