8

8920ADC Instruction Manual

Installation

Installation

Installation of the 8920ADC module is a process of:

1.

Placing the module in the desired frame slot,

2.

Cabling and terminating signal ports, and

3.

Configuring the module.

The 8920ADC module can be plugged in and removed from an 8900 Series
frame with power on. When power is applied to the module, LED indica-
tors reflect the initialization process (see

Power Up

on page 11

).

Frame Capacity

The 8920ADC module can be installed in all 8900 Series frames but with
varying maximum quantities determined by frame cooling capacity.

Table 1

provides the power capacity, cooling capacity, and maximum

module count for each frame type.

Note

Module capacity figures assume no other modules are in the frame.

Module Placement in the 8900 Frame

There are ten cell locations in the frame to accommodate either analog or
digital modules. These are the left ten locations. Refer to

Figure 1 on page 9

.

The two cells on the right are allocated for the power supplies. For addi-
tional information concerning the Power Supply module, refer to the

Gecko

8900 Frame Instruction Manual

.

The third cell from the right is allocated for the Frame Monitor or 8900NET
Network Interface controller modules. These modules provide health mon-
itoring and control options.

Table 1. Power, Cooling, and Module Capacity of 8900 Frames

Capacity Calculated

8900TX

Frame

8900TF

Frame

8900TFN

Frame

Power (W)

100

100

100

Recommended Module Cooling (W)

30

90

90

8920ADC Modules

7

10

10