Grass Valley AMX-1881 User Manual

Page 16

Advertising
background image

AMX-1881 HD/SD 8 AES Embedder
Guide to Installation and Operation

Page 16 of 19

AMX-1881

GSM Contribution

This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated with this
card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external applications. The
possible values for this contribution are related to the Overall alarm contribution:

• If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any available value
• If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is forced to follow the

Overall Alarm.



Log Events
iControl maintains a log of alarm events associated with the card. The log is useful for troubleshooting and identifying event
sequences. Click in the checkbox to enable logging of alarm events for each individual alarm.

At the bottom of the window are several other controls:

Overall Alarm and GSM Contribution follow card LED
Click in the checkbox to force the Overall alarm and GSM
contribution to be identical to the Card LED status

All Overall alarms and GSM contributions for which there is a

Card LED alarm will be forced to match the Card LED alarm

All Overall Alarms and GSM contributions for which there is

no Card LED alarm will be forced to Disabled


A warning box will open allowing you to confirm the action, since it
will result in changes to the configuration and there is no undo
function.

Copy to other cards
Click this button to open a panel that allows the alarm configuration
set for this card to be copied into another AMX-1881 card.

Select one or more destination cards from the list in the
window by clicking in the checkboxes, or all of them by
clicking in the All checkbox

Note that when you do a Copy Profile for this card (see
Annex 3), the alarm configuration is copied along with all the
other settings.




Get alarm keys
Click this button to open a save dialog where you can save a file
containing a list of all alarms on this card and their current values,
along with an Alarm Key for each. The alarm keys are useful for
system integration and troubleshooting.

The file is saved in Excel.csv format









OK, Apply, Cancel

OK accepts the settings and closes the window once the
card confirms that there are no errors.

Apply accepts the settings, but leaves the window open

Cancel closes the window without applying any changes, and leaves the previous settings intact