Aux-panels submenu – Grass Valley DD10 part 1 User Manual

Page 172

Advertising
background image

3.5 Install menu

Diamond digital DD10

166

3.5.7

AUX-PANELS SUBMENU

Press the associated key to select the AUX-PANELS submenu.

For the switchers DD5, DD10, DD20 and DD30, two types of AUX panels are avail-
able. Type CP-300 with 24 source selection keys and six bus delegation keys, and
type CP-330 with 48 source selection keys and six bus delegation keys.

In addition to the AUX panels, two types of status displays (UMDs) can be con-
nected to the same control bus. Type RP 1 UMD includes a display with eight char-
acters and type RP 2 UMD includes two displays with eight characters.

Since maximally 32 devices can be operated at the MPK bus, the number of the
connectable UMDs depends on the num ber of the installed AUX panels.

Number of UMD = 32 – number of AUX panels

The bus delegation keys can be assigned in menu AUX Panels to all buses. For
this purpose, the mixer types DD5 and DD10 require the connection of a menu
monitor.

As default, the bus delegation keys are assigned to the AUX buses AUX1 to AUX6.
Not all of the smaller mixer types have these buses.

AUX

AUX delegation

Advertising