NOTE: This procedure is intended for use by Grass Valley Service personnel or under the direct
supervision of Grass Valley Service personnel.

After you replace a disk controller board, you must import the configuration information from the
existing disks. This allows the new board to see the LUNs as previously configured.

1. After replacing the disk controller board, power up the K2 Solo 3G system.

Ignore SNFS messages that can open at any time during this procedure.

2. On the Windows desktop, open the

MegaRAID Storage Manager

icon.

3. When prompted, enter administrator credentials.

The MegaRAID Storage Manager main window opens.

4. In the MegaRAID Storage Manager main window tree-view, verify that drives are reported as

"Unconfigured Drives".

06 November 2012

K2 Solo 3G Service Manual

57

Service procedures