Installation, Frame capacity – Grass Valley Kameleon Series v.5.1.0 User Manual

Page 14

Advertising
background image

14

Kameleon Series Instruction Manual

Installation

Installation

To install the Kameleon modules:

1.

Place the passive rear module in a frame slot and tighten the screws on
each side of the rear module,

2.

Place the processor module in the corresponding front slot, and

3.

Cable the signal ports.

All Kameleon modules can be inserted and removed from a 2000 Series
Kameleon Frame with power on.

Note

Remove the front processing module before removing the rear I/O module.

Audio submodules must be installed or removed with the processing module
removed from the frame (processor module powered down).

Frame Capacity

Kameleon modules can be installed in any 2000 Series frame with a
2000NET interface.

Note

For optimum functionality, the 2000NET module should be running software
version 4.0.0 or later.

The one rackunit 2000T1DN (with dual 130W power supplies and 2000NET
module) or 2000T1DNG (with dual 130W power supplies, 2000NET and
2000GEN modules) frames have no Kameleon module capacity limitations.

The three rackunit 2000T3N (single 240W p/s, 2000FAN, and 2000NET
module) and 2000T3NG (single 240W p/s, 2000FAN, 2000NET and
2000GEN modules) frames can be fully populated with Kameleon modules
when the 2000FAN fan sled and two power sleds are installed.

Table 1

provides the maximum Kameleon module count for frame types.

Table 1. Power, Cooling, and Module Capacity of 2000 Series Kameleon Frames

Item

2000T3N/DNG

Kameleon Frame

Capacity

2000T1DN/NG

Kameleon Frame

Capacity

KAM-SD Module set

12

4

KAM-AV Module set

12

4

Advertising