Kayak HD — Installation and Service Manual

Section 4 — Maintenance

Fan Failure

CAUTION If a fan fails to operate it should be replaced immediately. The Kayak HD frame

shuts down when its internal temperature reaches 75-degrees C.

If there is a fan failure, the network panel displays an exclamation mark (

!

).

The fan board is hot pluggable (as are the power supplies and M/E boards).

CAUTION Do not attempt to run the Kayak HD system without functioning fans. This

can cause sever damage to circuit boards.

HD RAM Recorder Field Upgrade Procedure

In addition to the 6.8.8 software, for a field upgrade of HD RAM Recorder
on the Kayak HD, a new controller board (with DIMMs) and a software
license must be installed.

Field Upgrade Parts List

To upgrade from an earlier version of software/hardware to install HD
RAM Recorder, the following are required:

New

6910000xx

Controller Board.

USB Memory Stick with the HD RAM Recorder license and current
software

One or Two 4GB DIMMS

One 4GB DIMM for HD RAM Recorder

One 4GB DIMM for KlipCache (optional)

These release notes

Installing HD RAM Recorder Upgrade

CAUTION Use antistatic procedures to prevent electrical damage to sensitive electronic

components.

To install the HD RAM Recorder upgrade on the Kayak HD, complete the
following steps.

1.

Back up all current applications and environmental data from the
existing controller board to a USB stick or Sidepanel hard drive.

2.

Install 6.8.8 or later software to the control panel and Sidepanel, and
verify the installation.

3.

Install the RAMREC license from the USB memory stick provided.