Grass Valley CR Series v.3.2 User Manual

Page 197

Advertising
background image

185

CR Series

User’s Guide

Power Cord Retention for the PS0001 and PS0012 Power Supplies

Use the supplied retention strap to keep the AC power cord firmly connected to the power
supply. Follow these steps to use the strap:

1 Firmly insert the AC power cord into the power supply. Examine the last figure in this section

to see how the strap should be applied.

2 Placed the Velcro retention strap, fuzzy side up, on top of the power supply with the buckle

loop approximately 1 inch from the AC input side and the remaining strap around the cord
end and down:

3 Holding the buckle in place, lift the strap up and around the cord end so the strap overlaps

itself:

4 Holding the buckle loop in place, route the strap around the back of the supply diagonally

across so that it sticks out on the left below the output cord:

5 Continue the strap around toward the buckle loop and through the loop. Cinch the strap

tightly. While keeping tension, place the 2 inch strap end (with Velcro loops) down on the
fuzzy part to complete the process:

6 Examine the strap though its path around the cord and power supply. Be sure that no slack

exists and that it is tight the full length of the strap. If necessary, adjust and cinch it more
tightly.