6 using t o uc h-pr obes – HEIDENHAIN iTNC 530 (60642x-04) User Manual

Page 598

Advertising
background image

598

Manual Operation and Setup

14.6 Using t

o

uc

h-pr

obes

Writing the measured values from touch probe
cycles to datum tables

With the ENTER IN DATUM TABLE soft key, the TNC can write the

values measured during a touch probe cycle in a datum table:

Select any probe function

Enter the desired coordinates of the preset in the appropriate input

boxes (depends on the touch probe cycle being run)

Enter the datum number in the Number in table= input box

Enter the name of the datum table (complete path) in the Datum
table

input box

Press the ENTER IN DATUM TABLE soft key. The TNC saves the

datum in the indicated datum table under the entered number.

This function is active only if you have datum tables active

on your TNC (bit 3 in Machine Parameter 7224.0 =0).
Use this function if you want to save measured values in

the workpiece coordinate system. If you want to save

measured values in the machine-based coordinate system

(REF coordinates), press the ENTER IN PRESET TABLE

soft key (see "Writing the measured values from touch

probe cycles in the preset table" on page 599).

Danger of collision!

Note that during an active datum shift the TNC always

bases the probed value on the active preset (or on the

preset most recently set in the Manual operating mode),

although the datum shift is included in the position display.

Advertising