Workpiece alignment using 2 points – HEIDENHAIN iTNC 530 (60642x-04) User Manual

Page 609

Advertising
background image

HEIDENHAIN iTNC 530

609

14.8 Compensating w

o

rk

piece misalignment with a 3-D t

o

uc

h pr

obe

Workpiece alignment using 2 points

Select the probe function by pressing the PROBING

ROT soft key (soft-key row 2)

Position the touch probe at a position near the first

touch point

Select the probe direction perpendicular to the angle

reference axis: Select the axis by soft key

Start the probing procedure: Press the NC Start button

Position the touch probe at a position near the second

touch point

Probing: press the NC Start button. The TNC

determines the basic rotation and displays the angle

after the dialog Rotation angle =

Workpiece alignment:

Press the POSITION ROTARY TABLE soft key. The TNC will show

a warning that the touch probe must be retracted

Start alignment with NC Start: The TNC will position the rotary table

After the probing process, enter the preset number in which the

TNC is to save the active basic rotation in the Number in table:

input box

Saving the misalignment in the preset table

After the probing process, enter the preset number in which the

TNC is to save the measured misalignment in the Number in table:

input box.

Press the ENTRY IN PRESET TABLE soft key to save the angle value

as displacement in the rotary axis in the preset table

Danger of collision!

Retract the touch probe before alignment so as to exclude

a collision with the fixtures or workpieces.