Cycle parameters – HEIDENHAIN TNC 640 (34059x-01) Cycle programming User Manual

Page 257

Advertising
background image

HEIDENHAIN TNC 640

257

1

1

.7 SCALING (Cy

c

le 1

1

, DIN/ISO:

G72)

Cycle parameters

U

Scaling factor?

: Enter the scaling factor SCL. The

TNC multiplies the coordinates and radii by the SCL
factor (as described under "Effect" above). Input
range: 0.000000 to 99.999999

Example: NC blocks

11 CALL LBL 1

12 CYCL DEF 7.0 DATUM SHIFT

13 CYCL DEF 7.1 X+60

14 CYCL DEF 7.2 Y+40

15 CYCL DEF 11.0 SCALING

16 CYCL DEF 11.1 SCL 0.75

17 CALL LBL 1