Checking and changing Q parameters

9.6

9

TNC 640 | User's Manual for DIN/ISO Programming | 5/2013

259

You can have the Q parameters be shown in the additional status

display in the Manual, El. Handwheel, Single Block, Full Sequence

and Test Run operating modes.

If you are in a program run, interrupt it if required (for example,

by pressing the machine STOP button and the INTERNAL STOP

soft key). If you are in a test run, interrupt it.

Call the soft-key row for screen layout

Select the screen layout with additional status

display: In the right half of the screen, the TNC
shows the

Overview status form

Press the STATUS OF Q PARAM. soft key

Press the Q PARAMETER LIST soft key

The TNC opens a pop-up window in which you

can enter the desired range for display of the

Q parameters or string parameters. Multiple Q

parameters are entered separated by commas

(e.g. Q 1,2,3,4). To define display ranges, enter a

hyphen (e.g. Q 10-14).