Datum setting without a 3-d touch probe 15.5 – HEIDENHAIN TNC 640 (34059x-02) ISO programming User Manual

Page 465

Advertising
background image

Datum setting without a 3-D touch probe 15.5

15

TNC 640 | User's Manual for DIN/ISO Programming | 5/2013

465

Activating a datum from the preset table in the Manual
Operation mode

When activating a datum from the preset table, the

TNC resets the active datum shift, mirroring, rotation

and scaling factor.
However, a coordinate transformation that was

programmed in Cycle 19 Tilted Working Plane, or

through the PLANE function, remains active.

Select the

MANUAL OPERATION mode

Display the preset table

Select the datum number you want to activate, or

With the GOTO key, select the datum number that

you want to activate. Confirm with the ENT key

Activate the datum

Confirm activation of the datum. The TNC sets the

display and—if defined—the basic rotation
Exit the preset table

Activating a datum from the preset table in an NC program

To activate datums from the preset table during program run, use

Cycle 247. In Cycle 247 you define the number of the datum that

you want to activate (see User's Manual, Cycles, Cycle 247 SET

DATUM).