Yaskawa VS606 V74X V7 to V1000 User Manual

Page 19

Advertising
background image

PL.V1000-4X.01 Transition Guide 6/22/10

Page 19 of 32

Yaskawa America, Inc.

Product Transition Guide

PL. V1000-4X.01 Rev: 6/22/10

Terminal S6 function

selection

n055

7

H1-06

4

(3)

V74X

V1000-4X

n050~56 25

H1-01~H1-06 31

n050~56 26

H1-01~H1-06 B

n050~56 27

H1-01~H1-

06 1A

n052 0

H1-03 0

n056 34

H1-07 10, 11

n056 35

H1-07 67

Terminal S7 function

selection

n056

10

-

-

Terminal S7 does not exist

Terminal MA, MB, MC

function selection

n057

0

H2-01

E

n056 36

H1-07 75,76

n057~59 0

H2-01~03 E

n057~59 1

H2-01~03 0

n057~59 2

H2-01~03 2

n057~59 3

H2-01~03 1

n057~59 4

H2-01~03 4

n057~59 5

H2-01~03 5

n057~59 6

H2-01~03 B,18

n057~59 7

H2-01~03 17,19

Terminal P1 function

selection

(Open collector)

n058

1

H2-02

0

n057~59 8

H2-01~03 B,18

n057~59 9

H2-01~03 17, 19

n057~59 10

H2-01~03 10

n057~59 11

H2-01~03 8

n057~59 12

H2-01~03 3C

n057~59 13

H2-01~03 6

n057~59 14

H2-01~03 1E

n057~59 15

H2-01~03 7

Terminal P2 function

selection

(Open collector)

n059

2

H2-03

2

n057~59 16

H2-01~03 1A

n057~59 17

H2-01~03 3D

n057~59 18

n057~59 19

H2-01~03 3E

n057~59 20

H2-01~03 C

n057~59 21

H2-01~03 (1F), 20

Analog input FR (A1)

gain

n060

100%

H3-03

100%

Analog input FR (A2)

bias

n061

0%

H3-04

0%

Analog input filter time

constant

n062

0.10

sec

H3-13

0.03

sec

SI-T Watchdog error

operation selection

n063

0

-

-

-

No ML support

Operation at frequency

reference loss selection

n064

0

L4-05

0

n064 0

L4-05 0

n064 1

L4-05 1 and

L4-06 fref value

Analog output AM

Monitor type selection

n065

0

-

-

Use terminal FM for analog and terminal

MP for pulse output signals.

Drive

Parameter

Function

V74X

V1000-4X

Note

Param.

No.

Initial

Value

Set

Value

Param.

No.

Initial

Value

Set

Value

Advertising