V74x and v1000-4x specification differences – Yaskawa VS606 V74X V7 to V1000 User Manual

Page 30

Advertising
background image

Product Transition Guide

PL. V1000-4X.01 Rev: 6/22/10

PL.V1000-4X.01 Transition Guide 6/22/10
Page 30 of 32
Yaskawa America, Inc.

V74X and V1000-4X Specification Differences

Category

Feature

Item

V74X

V1000-4X

Power Section

Control Method

Sinewave PWM: V/f & OLV

Sinewave PWM: V/f & Current Vector

Power Section

Ratings

230v, 3ph.

0.125 to 10 HP

0.125 to 25 HP

Power Section

Ratings

460v, 3ph.

0.5 to 10 HP

0.5 to 25 HP

Power Section

Maximum Output

Frequency

400 Hz (800 Hz optional)

400 Hz (1000 Hz optional)

Power Section

Carrier Frequency

10 kHz (model dependent)

ND: 2 kHz; HD: 15 kHz (model dependent)

Power Section

F

c

Default (derate)

Constant

Swing PWM

Power Section

Braking Transistor

Circuit

Built-in to 10 HP

Built-in to 25 HP

Power Section

Short Circuit

Withstand Rating

18,000 A RMS Symmetrical

30,000 A RMS Symmetrical

Power Section

Control Method

IM only

IM / PM Control

Control Section

Digital Operator

Display

LED 4x 7 seg. (LCD option)

LED 5x 7 seg. (LCD option)

Control Section

Digital Operator

Number of Keys

6

8

Control Section

Copy Function

Built-in

Y-Stick USB copy unit option

Control Section

Microprocessor

Single

Dual

Control Section

Control Method

Pseudo-Closed Loop

No

Yes, w/ RP input

Control Section

Macro Applications

No

Yes

Control Section

Digital Input

Scan Rate

8 msec.

4 msec.

Control Section

Analog Input

Qty.

1 (Programmable)

2 (Programmable)

Control Section

Analog Input

Scan Rate

8 msec.

2 msec.

Control Section

Analog Input

Freq. Ref Voltage

15 Vdc

10.5 Vdc

Control Section

Analog Output

Scan Rate

8 msec.

2 msec.

Control Section

Pulse Input

Qty.

1 (Programmable)

1 (Programmable)

Control Section

Pulse Input

Input Frequency

33 kHz

33 kHz

Control Section

Pulse output

Qty.

1 (Programmable)

1 (Programmable)

Control Section

Pulse output

Output Frequency

1.44 kHz

33 kHz

Control Section

Digital Operator

Display

8 LED Indicators

6 LED Indicators

Control Section

Removable Terminal

Block

No

Yes (w / memory)

Control Section

Thermistor Input PTC

No

Yes

Control Section

2-Motor Control

No

Yes

Control Characteristics

Overload Capacity

150% for 1 min.

ND: 120% for 1 min.; HD: 150% for 1 min.

Control Characteristics

Starting Torque

150% @ 3 Hz (V/f)

150% @ 3 Hz (V/f),

200% @ 0.5 Hz (OLV)

Control Characteristics Speed Control Range

Open Loop for PM

N/A

1:10

Control Characteristics

Output Frequency

Resolution

0.01 Hz

0.001 Hz

Control Characteristics

Auto-Tuning

Automatic/OnLine

No

Yes, R1 and Rotational

Control Characteristics

Elapse Time

No

Yes (Power up or Run)

Control Characteristics

Fault Storage

Last 4

Last 10 w / Elapsed Time Meter

Control Characteristics

Fault Record

No Trace Data Points

15 Trace Data Points

Control Characteristics

High Current Alarm

HCA

No

Yes, 150%

Control Characteristics

OV Suppression

Option- CASE

Standard

Control Characteristics

Torque Detection

Over-Torque

Over and Under-Torque