Yaskawa VS606 V74X V7 to V1000 User Manual

Page 25

Advertising
background image

PL.V1000-4X.01 Transition Guide 6/22/10

Page 25 of 32

Yaskawa America, Inc.

Product Transition Guide

PL. V1000-4X.01 Rev: 6/22/10

Upper voltage limit for

energy saving at 60Hz

n159

120%

-

-

-

No setting available.

Upper voltage limit for

energy saving at 6Hz

n160

16%

Power detection hold

during voltage tuning

n161

10%

Power detection filter

time constant

n162

5

(20 ms)

b8-05

20 ms

PID output gain

n163

1.0

b5-10

1.0

PID feedback value

selection

n164

0

H3-09

2

V74X

V1000-4X

n164 0

Term. A2:

H3-09 0, H3-10 B

H3-10

0

n164 1

Term. A2:

H3-09 2, H3-10 B

n164 2

Term. A2:

H3-09 3, H3-10 B

n164 3

– (no operator poti)

H6-01

0

n164 4
n164 5

H6-01 = 1

When terminal A2 is used always check

the position of DIP switch S1

Braking resistor over

heat protection

(ERF type)

n165

0

L8-01

0

n165 0

L8-01 0

n165 1

L8-01 1

Input open phase

detection level

n166

0%

L8-05

o2-09

dep.

The input phase loss detection level and

time can not be set in V1000-4X. The

phase loss detection can be enabled/

disabled by setting L8-05.

Input open phase

detection time

n167

0.0 sec

Output open phase

detection level

n168

0%

L8-07

o2-09

dep.

The output phase loss detection level and

time can not be set in V1000-4X. The

phase loss detection can be enabled/

disabled by setting L8-07.

Output open phase

detection time

n169

0.0 sec

Memobus Enter

command selection

n170

0

-

-

V1000-4X accepts Enter commands at

any time.

Frequency reference bias

upper limit (up/down2)

n171

0.0%

d4-08

0.0%

Frequency reference bias

lower limit (up/down2)

n172

0.0%

d4-09

0.0%

DC braking P-gain

n173

83

No need to set up in V1000-4X

DC braking integral time

n174

25

Low speed carrier

frequency reduction

n175

0

L8-38

0

n175 0

L8-38 0

n175 1

L8-38 1

COPY function selection

n176

rdy

o3-01

0

n176 rdy

n176 rEd

o3-01 1

n176 CPy

o3-01 2

n176 vFy

o3-01 3

n176 vA

n176 Sno

Drive

Parameter

Function

V74X

V1000-4X

Note

Param.

No.

Initial

Value

Set

Value

Param.

No.

Initial

Value

Set

Value

Advertising