PL. V1000-4X.01 Rev: 6/22/10

Carrier frequency

selection

n080

4

C6-02

o2-04

dep.

V74X

V1000-4X

Carrier frequency upper

limit

C6-03

C6-02

dep.

n080 1

C6-02 1 (2kHz)

Carrier frequency lower

limit

C6-04

C6-02

dep.

n080 2

C6-02 2 (5kHz)

Carrier frequency

proportional gain

C6-05

0

n080 3

C6-02 3 (8kHz)

n080 4

C6-02 4 (10kHz)

n080 7~9

C6-03/04/05 must

be used

Momentary power loss

detection selection

n081

0

L2-01

0

n081 0

L2-01 0

n081 1

L2-01 1

n081 2

L2-01 2

Automatic restart

attempts

n082

0

L5-01

0

Jump frequency 1

n083

0.0 Hz

d3-01

0.0 Hz

Jump frequency 2

n084

0.0 Hz

d3-02

0.0 Hz

Jump frequency 3

n085

0.0 Hz

d3-03

0.0 Hz

Jump frequency

bandwidth

n086

0.0 Hz

d3-04

1.0 Hz

Operation time counter

selection

n087

0

o4-02

0

n087 0

o4-02 0

n087 1

o4-02 1

Accumulated operation

time

n088

0 H

o4-01

0 H

DC injection braking

current

n089

50%

b2-02

50%

DC injection time at stop

n090

0.5 sec

b2-04

o2-09

dep.

DC injection time at start

n091

0 sec

b2-03

0 sec

Stall prevention during

deceleration

n092

0

L3-04

1

n092 0

L3-04 1

n092 1

L3-04 0, 3

Stall prevention level

during acceleration

n093

170%

L3-02

150%

Stall prevention level

during run

n094

160%

L3-06

160%

Output frequency

detection level (DO)

n095

0.00 Hz

L4-01

0.0 Hz

Over / under torque

detection

n096
(OL)

n117
(UL)

0

L6-01

L6-03

0

n096,117 0

L6-01/03 0

n096,117 1

L6-01/03

1(OL),5(UL)

n096,117 2

L6-01/03

3(OL),6(UL)

n096,117 3

L6-01/03

2(OL),7(UL)

n096,117 4

L6-01/03

4(OL),8(UL)

Drive

Parameter

Function

V74X

V1000-4X

Note

Param.

No.

Initial

Value

Set

Value

Param.

No.

Initial

Value

Set

Value

Advertising