Cpf00, Display and outputs status and remedy for alarm – Yaskawa Large Capacity Sigma II Series User Manual

Page 372

Advertising
background image

8.2 Troubleshooting

8-33

8

„

CPF00

CPF00: Digital Operator Transmission Error 1
This alarm is not stored in the alarm trace-back function memory.

This alarm is also temporarily displayed when an option unit and the Digital Operator are
used at the same time and communications between the option unit and the SERVOPACK
last for more than one second. Operation with the Digital Operator is disabled during this
period.

Display and Outputs

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

Not specified

Cause

Remedy

A

Cable defective or poor contact between
Digital Operator and SERVOPACK.

• Check connector connections.
• Replace cable.

B

Malfunction due to external noise.

Separate Digital Operator and cable from
noise source.

C

Digital Operator defective.

Replace Digital Operator.

D

SERVOPACK defective.

Replace SERVOPACK.

Digital Operator connected to
SERVOPACK after power
turned ON.

A, B,
C, D

At power ON. Digital Operator
connected before SERVOPACK
power turned ON.

A, B,
C, D

Advertising