STEP 11.11

a) Insert a blank sheet of paper into the rear paper path using the
11” side as the side that enters the printer first. Wait until the paper

has been accepted and that there are no paper skew issues or front
panel errors. Now you may click on the “Print Calibration Plot” button.

b) With NO media in the printer click on the “Scan Calibration Plot”.
You may notice some sounds coming from the printer. Wait until the
front panel shows the „No Media‟ symbol. Place the plotted sheet of

paper from step 1 into the rear paper path using the 17” side with the
printed arrows, face up into the printer first. You will notice that the

printer will not automatically accept the media; you will have to press
the „OK‟ key on the front panel. It may be best for someone to do
this from the printers left hand side so the user can hold the plot with
their left hand and use there right hand to press the button. The

printer will now accept the media and once skew has been
conformed, scanning of the plot will commence.
c) Click on the “Reset After Scan” button