Blueplanet as part of a pv installation, 1 design of installation, 7 blueplanet as part of a pv installation – KACO blueplanet 1502x User Manual

Page 23

Advertising
background image

blueplanet Installation Instructions 1502x - 5002x

Page 23

Section 7 ·

blueplanet as part of a PV Installation

7 blueplanet as part of a PV Installation

7.1 Design of installation

A sample design of a grid-connected PV installation using a blueplanet is shown below in the overview circuit diagram.

blue planet Inverter

Main circuit breaker

Circuit

breaker

Utility meter

KWh

PV array

PV array

blue planet Inverter

External

DC switch

Circuit

breaker

optional

AC switch

optional

AC switch

External

DC switch

Figure 7.1 Single-line overview circuit diagram

for an installation with two inverters

A summary of the components:

DC terminal point:

Two PV strings can be connected in parallel either at a DC terminal point between the solar generator and the inverter

or directly on the inverter (terminals for three strings are provided on the inverter). Of course, you can also connect the

strings directly to the solar generator and then run just one negative and one positive lead to the inverter. External fusing

may be required, refer local and national electric codes.

External DC switch:

In order to be able to disconnect the inverter on the PV generator side from sources of voltage, use the external DC

disconnect switch.

External AC switch:

In order to be able to disconnect the inverter on the PV generator side from sources of voltage, use the external AC

disconnect switch.

Line overcurrent protection:

In order to protect the wiring, the inverter’s supply leads should be secured with circuit breakers or fuses as appropriate.

The circuit breakers or fuses that are used should be appropriate to the length and cross-section of the wiring and fulfill

applicable standards and directives (5.3: Electrical connection – grid connection).