3 confi guring the local area network – Magnum Energy ME-MW-E User Manual

Page 10

Advertising
background image

6

© 2011 Magnum Energy, Inc.

2.0 Installation/3.0 Using data.magnumenergy.com

2.3 Confi guring the Local Area Network

The MagWeb communicates with Magnum Energy’s servers by establish-

ing an outgoing TCP/IP connection when data is received. At the default

30-second data interval, the MagWeb system will send approximately 2.5

megabytes of data per day.
By default, the MagWeb determines network confi guration using DHCP or

BOOTP. This information includes the MagWeb’s LAN IP address and router

IP address. Most networks provide DHCP service and therefore the MagWeb

usually does not require any confi guration.
For details on confi guring the MagWeb for non-DHCP networks or for special

confi gurations, consult the troubleshooting section of this manual.

2.4 Registering on data.magnumenergy.com

Visit http://data.magnumenergy.com/ for up-to-date instructions on

registering and creating an account.

3.0 Using data.magnumenergy.com

Instructions for viewing data from your MagWeb device is available at:

http://data.magnumenergy.com/.

2.2.1 Connecting MagWeb to a Local Area Network and the Internet

The MagWeb should be attached to the Local Area Network (LAN)/Ethernet

network using the supplied 8-conductor CAT5 Ethernet cable. This connection

is made directly to a network access device such as a router, or through a

wall jack that connects to a network access device.

Info: The MagWeb is plugged directly into a wired Ethernet

connection using the supplied Ethernet cable. The Ethernet

cable run is limited to 100 meters in total length. The Ethernet

cable must be connected to the Ethernet network and to the

MagWeb device before the MagWeb is connected to the inverter.

Info: Ensure that the MagWeb is connected to an “always on”

internet connection.

2.2.2 Connecting MagWeb to a Single Inverter

Use the supplied four-conductor remote cable to connect the MagWeb

device’s TO INVERTER port to the Magnum inverter’s Remote port.

2.2.3 Connecting MagWeb to a Single Inverter and Remote Control

The MagWeb device, using the supplied cable, can be located near the remote

or near the inverter. To mount the MagWeb device near the inverter, route

the 6ft four-conductor remote cable from the inverter’s Remote port to the

MagWeb device’s TO INVERTER port. Use the longer 50ft cable — supplied

with the remote control — to connect the MagWeb device’s TO REMOTE port

to the remote control. To mount the MagWeb device near the remote, swap

the 6ft remote cable with the 50ft remote cable.

Advertising