1 magweb device led status – Magnum Energy ME-MW-E User Manual

Page 11

Advertising
background image

© 2011 Magnum Energy, Inc.

7

4.0 Using LED Indicators to Determine MagWeb’s Status

4.0 Using the LED Indicators to Determine the
MagWeb’s Status

There is a bi-color LED indicator on top of the MagWeb device (next to the

Ethernet port) to indicate the MagWeb’s status. When the device is fi rst

powered up, the LED blinks red and green while going through a self-test.

Once the self-test is complete, use the table below and the LED indicator on

your device to determine the MagWeb’s operating status.
If the MagWeb device does not function correctly, use Table 4-1 to help fi nd

a solution.

4.1 MagWeb Device LED Status

Table 4-1, MagWeb Device’s LED Indicator Guide

LED Status

Meaning

OFF

Ensure the inverter has power and the cables

are correctly seated into the MagWeb device.

Red ON, Green ON,

Red ON, Green ON

Power-up sequence (1-second interval

between each color). The MagWeb device is

performing a self-test – this occurs when fi rst

connected to power.

Green

ON

Normal operation: the MagWeb device is

correctly transmitting and receiving with

network devices.

Green

BLINKING

Remote not connected, or device is not able to

communicate with remote display.
Ensure the correct cable is connected between

the MagWeb and the remote. If the remote/

router display is off, refer to the remote/router

owner’s manual for troubleshooting.

Red

ON

The power-up sequence failed. Contact

Magnum Energy.

Red

BLINKING

No communication, or an unrecognizable

communication on the network.
Check the remote cable; ensure it is connect-

ed correctly.
Important: Ensure the RJ11 connectors are

pushed into the correct port; you should feel/

hear a “click” when the connection is made.

Advertising