Connecting to the Network

3-6 Installation

Figure 3-2 Installing Module into N3, N1, or N5 Chassis (N3 shown)

Connecting to the Network

This section provides the procedures for connecting unshielded twisted pair (UTP) segments from 
the network or other devices to the 2G4082‐25 (“

Connecting UTP Cables

” on page 3‐6). 

Connecting UTP Cables

The fixed RJ45 front panel connections of the 2G4082‐25 are 10/100/1000 Mbps ports. These ports 
have internal crossovers, and also support automatic‐polarity sensing when configured for 
automatic‐negotiation.

If automatic‐negotiation is not activated on a port, use a straight‐through cable when connecting a 
workstation to the port. When connecting a networking device to the port, such as a bridge, 
repeater, or router, use a crossover cable.

If a port is set for auto‐negotiation, automatic‐polarity sensing is also activated. Automatic‐
polarity sensing eliminates the need for a crossover cable, regardless if the connection is to another 
network device or a workstation.

1 Card guides

5 Upper locking tab (shown in closed position)

2 Slot 1 (Top slot is slot 3.)

6 Lower locking tab (shown in closed position)

3 Module card

7 Backplane connectors

4 Metal back panel

FAN

STATUS

7C203-1

REDUNDANCY

PWR

100-125V~12.0A

200-240V~6.0A

50/60 Hz

0

7C203-1

REDUNDANCY

PWR

100-125V~12.0A

200-240V~6.0A

50/60 Hz

0

COM

OFFLINE/ RESET

MGMT

CPU

1

2

GR

OUP

SELECT

1X

11X

13X

12X

14X

23X

G R O U P

1

24X

G R O U P

2

GR

OUP

1

2

3

4

5

6

7

8

9

10

11

12

DFE

2G4082-25

Gb ENET

Б

Ж

Д

В

А

Г

Е

Note: If the DFE-Platinum module is being installed in a network using Link Aggregation, there are
rules concerning network cables and port configurations that must be followed for Link Aggregation
to operate properly. Before connecting the cables, refer to the Enterasys Matrix DFE-Diamond/
Platinum Series Configuration Guide
for the configuration information. For details on how to obtain
manuals, refer to the

Related Documents

” on page xii

.

Note: All RJ45 front panel ports on the 2G4082-25

 

support Category 5 Unshielded Twisted Pair

(UTP) cabling with an impedance between 85 and 111 ohms. Category 3 cable may be used if the
connection is going to be used only for 10 Mbps.