Com port pinout assignments, Regulatory compliance – Enterasys Networks Enterasys Matrix 9034310-01 User Manual

Page 48

Advertising
background image

COM Port Pinout Assignments

A-2 Specifications

COM Port Pinout Assignments

The COM port is a serial communications port for local access to Local Management. Refer to 

Table A‐2

 for the COM port pin assignments.

Regulatory Compliance

The 2G4082‐25 meets the safety and electromagnetic compatibility (EMC) requirements listed in 

Table A‐3

:

Environmental

Operating Temperature

5°C to 40°C (41°F to 104°F)

Storage Temperature

-30°C to 73°C (-22°F to 164°F)

Operating Relative Humidity

5% to 90% (non-condensing)

Table A-1 Specifications for 2G4082-25 (continued)

Item

Specification

Table A-2 COM Port Pin Assignments

Pin

Signal Name

Input/Output

1

Transmit Data (XMT)

Output

2

Clear to Send (CTS)

Input

3

Data Set Ready (DSR)

Input

4

Receive Data (RCV)

Input

5

Signal Ground (GND)

NA

6

Request to Send (RTS)

Output

7

Data Terminal Ready (DTR)

Output

8

Data Carrier Detect (DCD)

Input

Table A-3 Compliance Standards

Regulatory Compliance

Standards

Safety

UL 60950, CSA C22.2 No. 60950, 2006/95/EC, EN 60950, IEC
60950, EN 60825, 21 CFR 1040.10.

Electromagnetic Compatibility (EMC)

47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN 55022,
EN 61000-3-2, EN 61000-3-3, EN 55024, AS/NZS CISPR 22,
VCCI V-3.

Advertising
This manual is related to the following products: