EverFocus EMV1200 User Manual

Page 63

Advertising
background image

55

GPS Loss:

Figure 4-18 Alarm – Event – GPS Loss


Buzzer: Check box to enable buzzer when GPS is lost.
Email Notify: Check box to enable email notification when GPS is lost. Email operation requires that valid

email settings have been entered in the Network Setting/Email setup screen.
Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and

setting up Alarm Server in Network Setup menu)
Alarm Output:
This will transmit a signal through the alarm output

relay. It can be set to either “NONE” (not

active), “1” (active) or “2 (active).
Output Type:
Output action when alarm is triggered.

Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “Enter” key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.

Timeout Duration: The amount of time the buzzer sounds when GPS is lost. Duration selectable from 1 to
150

seconds.

NOTE: This function only checks the physical connection (link) to the network. Any network behavior
that blocks data connectivity (blocked ports, IP addressing errors, etc.) is not detected by this function.

Click

button to return to the previous level of menu.