4.4.6 Alarm-GPS Event Action

Press

to enter GPS Event Action Menu.

Figure 4-22 Alarm – GPS Event Action

Alarm Output: This will transmit a signal through the alarm output

relay. It can be set to either “NONE” (not

active), “1” (active) or “2 (active).

Output Type: Output action when alarm is triggered.

Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “Enter” key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.

Timeout Duration: The amount of time the buzzer sounds when GPS event occurs. Duration selectable

from 1 to 150

seconds.

Pre-alarm Record: Check box to start copying recorded video to the hard disk from 5 seconds before the

video loss. (Pre-alarm recording rate will follow the “Normal” frame rate setting)
Email Notify:
Check box to enable email notification when GPS event occurs. Email operation requires

that valid email settings have been entered in the Network Setting/Email setup screen.
Network Alarm:
Check box to send out a network alarm to client PC. (requires PowerCon software and

setting up Alarm Server in Network Setup menu)

Click

button to return to the previous level of menu.