The identify LED can be flashed with or without a drive inserted

in the slot. Consequently, the identify LED indicates which slot

is housing the faulty device and shows the user in which slot a

replacement drive should be installed.

Note:

Issuing a SCSI reset message or SCSI bus device reset

message does not change the state of the indicator lights.

5. Connecting the control plane