1.2. SAFETY (INSTALLATION).

7

DO NOT usE tHE comPrEssor If It Is fAuLtY. Ensure

that the compressor is in good condition before use.

If the compressor is noisy or vibrates excessively when

running, stop it immediately. If in any doubt do not use the unit

and contact an electrician/service agent.

3

oPErAtE tHE comPrEssor At tHE rAtED VoLtAGE.

operate the compressor at the voltage specified on the

electric data plate. You could damage or burn-out the motor

and other electric components if the compressor is operated at

a higher or lower voltage than its rated voltage.

3

usE tHE comPrEssor corrEctLY. operate the

compressor in compliance with the instructions provided in this

manual.

DO NOT allow children or those who are not familiar

with it to use the compressor.

1.3. SAFETY (OPERATIONAL AREA/ENVIRONMENTAL).
3

oPErAtIonAL ArEA. Keep the work area clean and remove

any tools or unnecessary items that are not required. Install

the compressor on a firm surface away from any heat sources.

3

usE tHE comPrEssor In A WELL VEntILAtED ArEA.

Ensure there is adequate ventilation space all around the

compressor.
7

DO NOT usE tHE comPrEssor In tHE PrEsEncE of

fLAmmABLE LIquIDs or GAs. the compressor may

produce sparks while running.

DO NOT use the compressor

where there may be paints, petrol (gasoline), chemical

compounds, glues or any other flammable or explosive

material.
3

KEEP unAutHorIsED PErsons AWAY from tHE

WorKInG ArEA. All non-essential persons must be kept at a

safe distance from the operational area. Prevent children or

anyone else from touching the power supply cable of the

compressor.
7

DO NOT use the compressor outdoors. DO NOT

install the compressor in damp or wet locations or in areas

where condensation may form.

7

DO NOT cover the compressor or restrict air flow around the

machine whilst operating.

3

If tHE comPrEssor Is usED for PAIntInG JoBs.

a)

DO NOT work in closed rooms or near naked flames.

b)

check that the area selected for spraying is provided with

an air change system or adequate ventilation.

c) Wear face and nose mask.

3

When the compressor is not in use, it should be switched

off, isolated from the mains supply and the air drained

from the tank.

3

storE tHE comPrEssor APProPrIAtELY. If the

compressor is not used immediately, it must be stored in a dry

place away from atmospheric agents until it is installed.

1.4. SAFETY (AIR/PRESSURE).

WARNING! THE AIR TANk IS A PRESSuRE vESSEl ANd

THE fOllOWINg SAfETY MEASuRES APPlY:

7

dO NOT tamper with the safety valve and dO NOT modify

or alter the tank in any way. dO NOT strap anything to the

tank.

7

dO NOT subject the tank to impact, vibration or to heat

and dO NOT allow contact with abrasives or corrosives.

7

DO NOT drill, weld or deform the compressed air tank.

7

DO NOT unscrEW tHE outLEt connEctIon WHEn

tHE tAnK Is PrEssurIsED.

DO NOT unscrew the

connection for any reason whatsoever without first checking if

the tank is discharged.

3

Ensure the air supply valve is turned off before disconnecting

the air supply hose.

PNEUMATIC CIRCUIT.

use recommended pneumatic hoses. read the instructions

regarding any accessory used with the compressor. Ensure

the safe working pressure of any air appliance used exceeds

the compressor maximum pressure.

3

Ensure the air hose is not tangled, twisted or pinched.

7

DO NOT operate the compressor without an inlet air filter.

1.5. SAFETY (TRAINING/GOOD PRACTICE).
7

DO NOT allow anyone to operate the compressor unless they

have received full instructions and adequate training.

3

KEEP tHEsE usE AnD mAIntEnAncE InstructIons

for future reference and make them available to the

compressor

operator. the operator must be familiar

with all the controls and

compressor characteristics

before starting to work with the

machine.

3

AVoID AccIDEntAL stArt-uP. Ensure that the main switch

is turned off before connecting the compressor to the

electrical power supply. never move the compressor while it is

connected to the electrical power supply or when the tank is

pressurised.

3

PrEcAutIons for tHE PoWEr suPPLY cABLE.

DO NOT

disconnect the power supply plug by pulling on the cable. Keep

the cable away from heat, oil and sharp edges.

DO NOT stand

on the electrical cable or trap it under heavy weights.

3

LooK AftEr tHE comPrEssor WItH cArE. follow the

maintenance instructions. Inspect the power supply cable on a

regular basis and if damaged it must be repaired or replaced

by an authorised service centre. check the outside

appearance of the compressor, ensuring that all is in order.

contact your nearest sealey dealer if necessary.

3

cHEcK for fAuLtY PArts or AIr LEAKs. Before each

use, visually inspect the compressor. If a safety guard or other

part is damaged, they must be checked carefully to evaluate

whether they continue to provide the intended protection.

check the alignment of moving parts, hoses, gauges,

pressure reducers, pneumatic connections and every other part

that may be crucial for the normal operational efficiency of the

compressor. All damaged parts must be properly repaired or

replaced by an authorised service centre or replaced following

the instructions provided in instruction manual.

3

turn tHE comPrEssor off WHEn It Is not In usE.

When the compressor is not in use turn the main on/off

switch to the off position (“0”).

7

DO NOT DEfAcE tHE cErtIfIcAtIon PLAtE AttAcHED

to tHE EnD of tHE comPrEssor tAnK.

1.6. SAFETY (PERSONAL/MECHANICAL).
7

DO NOT usE tHE comPrEssor WItHout tHE sAfEtY

GuArDs fIttED. never use the compressor without all the

safety guards properly fitted in their correct place. If these parts

are to be removed for maintenance or servicing purposes,

ensure that they are correctly reinstalled before using the

compressor again.

7

DO NOT Put oBJEcts or PArts of tHE BoDY Into

tHE ProtEctIon GrILLs. never put your hands, fingers or

other parts of the body near moving parts of the compressor.

to do so may cause physical injuries and damage to the

compressor.
7

DO NOT toucH Hot PArts of tHE comPrEssor.

to avoid burns do not touch the compressor cylinder, cylinder

head,

motor or pipe from head to tank as these may be hot and

will remain so for some time after shutdown.

3

ALWAYs WEAr sAfEtY GoGGLEs or equivalent means of

eye protection. never direct compressed air towards any part

of your body or that of others.

3

WEAr APProPrIAtE cLotHInG.

DO NOT wear unsuitable

clothing, ties or jewellery as these may get caught up in moving

parts. tie back long hair or wear a cap to cover your hair if

necessary.
3

ProtEct YoursELf AGAInst ELEctrIc sHocKs. Avoid

accidentally touching the metal parts of the compressor with

your body, such as pipes, the tank or metal parts connected to

earth. never use the compressor where there is water or in

damp rooms.