screw tail-piece attachment (2) into drain tap(3) below sight

glass. Attach suitable hose and open tap to drain.

once emptied, close drain tap and

remove hose and tail-piece.

fill with oil through plug hole (1) until oil is half way up the

sight glass (4). Replace plug and refit shroud.

Once the oil and oil filter have been changed

leave the compressor to run for roughly 5

minutes then turn it off and check the oil

level again. Add oil if necessary.

check the oil level once a week.

6.3.

REPLACING THE OIL FILTER CARTRIDGE.

6.3.1.

Replace the oil filter cartridge after the first 500 hours of use

then every 2500 hours and in any event each time the oil is

changed.

6.3.2.

remove the upper plastic shroud to gain access

to inside the compressor.

6.3.3.

Remove filter cartridge (fig.9.1.) using a strap wrench and

replace with a new one.

6.3.4.

Lubricate the sealing gasket before screwing the filter

cartridge tight.

6.3.5.

Tighten the new filter cartridge manually.

6.4

REPLACING THE OIL SEPARATOR FILTER CARTRIDGE.

6.4.1.

Replace the oil separator filter cartridge after the first 500

hours of use then every 2500 hours and in any event

each time the oil is changed.

6.4.2.

remove the upper plastic shroud to gain access to inside

the compressor.

6.4.3.

Remove filter cartridge (fig.10.2.), using a strap wrench and

replace with a new one.

6.4.4.

Lubricate the sealing gasket before screwing the filter

cartridge tight.

6.4.5.

Tighten the new filter cartridge manually.

6.5.

REPLACING THE AIR FILTER CARTRIDGE.

6.5.1.

remove the upper plastic shroud to gain access to inside

the compressor.

6.5.2

open the plastic cover.

6.5.3.

Replace the air filter cartridge and replace the cover.