6.6.

CLEANING THE AIR/OIL RADIATOR.

6.6.1.

remove upper and lower plastic shrouds to gain access to

inside the compressor.

6.6.2.

Blow compressed air through the radiator, from inside

outwards,making sure that no dirt settles inside the

compressor. (fig.12.)

PROBLEM

POSSIBLE CAUSE

SOLUTION

compressor not starting.

no mains power.

check mains power, including

supply fuses and breakers.

compressor stops,

thermal trip activated.

Excessive air/oil mixture

temperature.

check oil level

check that air/oil radiator is not

blocked.

compressor stops.

motor overheating: motor thermal

relay activated.

check that power supply is correct.

check for loose cable

connections and hot cables

check that motor cooling intake is

not blocked or obstructed.

to resart the compressor:

allow to cool for a few minutes and

press the on/off switch.

7. TROUBLESHOOTING

To reset oil temperature trip: unscrew cap.

Then use pointed object to press trip button,

replace cap.