Fig.1, Fig.2, Introduction & specifications 3. preparation – Sealey SSC11003 User Manual

Page 3: Installation

Advertising
background image

fig.1

2. INTRODUCTION & SPECIFICATIONS

3. PREPARATION

1.7. SAFETY (MAINTENANCE/PARTS).

WARNING! Compressor must only be serviced by an

authorised agent. DO NOT tamper with, or attempt to

adjust, pressure switch or safety valve.

3

sPArE PArts. use only original and identical spare parts to

replace worn or damaged ones. repairs must be made

exclusively by an authorised service agent.

3

mAIntEnAncE. regular maintenance of the compressor is

essential to ensure a long working life. follow the maintenance

schedule detailed in these instructions.

7

DO NOT disassemble compressor for any reason. the unit must

be checked by qualified personnel only.

3

dRAIN condensate from tank at least every week, inspect

inside walls for corrosion every three months and have a

detailed tank inspection carried out annually. Tank shell

must not fall below the certified thickness at any point.

3

When not in use, store the compressor carefully in a safe, dry,

childproof location.

3

KEEP tHE IntAKE GrILLs cLEAn. Keep the motor

ventilation grills clean. clean these grills regularly if the work

area is particularly dirty.

7

DO NOT cLEAn PLAstIc PArts usInG soLVEnts.

solvents such as petrol (gasoline) and thinners or other

compounds that contain hydrocarbons may damage the plastic

parts. clean them with a soft cloth and soapy water or other

suitable liquids.

3

usE orIGInAL sPArE PArts onLY. the use of non-original

spare parts will invalidate the warranty and could seriously

damage the compressor. original spare parts are available

from your local sealey dealer.

3 moVInG or mAIntAInInG tHE comPrEssor. Disconnect

the compressor from the electric power supply and completely

discharge the pressure from the tank before moving it or

carrying out any service, inspection, maintenance, cleaning,

replacing or inspection of parts.

WARNING! If an electrical fuse blows, ensure that it is

replaced with one of identical type and rating.

1.8. SAFETY (COMMON SENSE).

WARNINg: The warnings, cautions and instructions

discussed in this instruction manual cannot cover all

possible conditions and situations that may occur. It must

be understood that common sense and caution are factors

which cannot be built into this product, but must be

applied by the operator.

3

WArnInG. Pay attention to everything you do. use your

common sense.

DO NOT use the compressor if you are tired.

the compressor must never be used if you are under the

influence of alcohol, drugs or intoxicating medicines.

DANGER! DO NOT DIrEct tHE JEt of comPrEssED AIr

DIrEctLY toWArDs Your BoDY. to avoid all risks never

direct the jet of air towards other people or animals.

7

DO NOT stoP tHE comPrEssor BY PuLLInG on tHE

PoWEr suPPLY cABLE (unless in an emergency). use the

on/off buttons on the control panel to stop the compressor.

7

DO NOT moDIfY tHE comPrEssor In AnY WAY.

contact your local sealey dealer for all repairs required. Any

unauthorised modification may impair the efficiency of the

compressor and may also cause serious accidents for those

who do not have the technical skill required to make such

modifications.
3

WE rEsErVE tHE rIGHt to mAKE moDIfIcAtIons

WHErE nEcEssArY WItHout notIcE.

Original Language Version

compact high performance screw compressor providing high volume

and continuous output of air with low running costs. one of the most

economical ways to get compressed air 24/7 with minimal downtime.

Very few moving parts means servicing/maintenance is less frequent

and less expensive compared to equivalent piston compressor.

features an insulated class f 3hp motor with IP44 protected control

box and an insulated outer casing to minimise noise (59dB(A) at 1mtr)

and offers protection to inner components. All routine maintenance

functions are easily accessible and there is clear instrumentation

showing tank and line pressures separately. Also fitted with drain valve

tap at base of unit to ensure easy function tank drain when required.

Model No:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . SSC11003

motor output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3hp

Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . 230V - 1ph

rated supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15A

noise Level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59dB(A)

maximum free Air Delivery: . . . . . . . .10.6cfm (300 ltr/min)

maximum Pressure: . . . . . . . . . . . . . . . . . . . . .131psi/9bar

receiver capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . .100ltr

Dimensions (W x D x H):. . . . . . . . . . . 520 x 920 x1100mm

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88kg

Plug (not fitted):. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16A

3.1 remove compressor from packaging and inspect for any

shortages or damage. If anything is found to be missing or

damaged contact your supplier.

3.2 save the packing material for future transportation of the

compressor. We recommend that you store the packing in a

safe location, at least for the period of the guarantee. then, if

necessary, it will be easier to send the compressor to the

service centre.

3.3 Assemble the two fixed wheels and the castor wheel to the

SAC11003 as shown in fig.1.

3.4 confirm that the mains voltage corresponds with the voltage

shown on the compressor data plate.

3.5 site in a well ventilated place, protected against atmospheric

pollution and not in a place subject to explosion hazard. If the

surface is inclined and smooth, check if the compressor moves

while in operation – if it does, secure the wheels with two

wedges. If the surface is in a raised position, make sure it

cannot fall, securing it in a suitable way.

4. INSTALLATION

3.6. STORING THE PACKED AND UNPACKED COMPRESSOR.

.

If the compressor is not to be unpacked immediately store it in

a dry place at a temperature between +5°c and +40°c and

sheltered away from the weather. If the compressor is not

used immediately after unpacking it, place sheets over it to

protect it from dust, which may settle on the components.

the oil is to be replaced and the operational efficiency of the

compressor is to be checked if it is not used for long periods.

fig.2

4.1. to ensure good ventilation

and efficient cooling, the

compressor's air intake must

be at least 500mm from any

wall (fig.2)

ssc11003 Issue: 1 - 03/05/13