Important safety guidelines, Save these instructions, Notice – Emerson Liebert XDR User Manual

Page 2: Warning, Caution

Advertising
background image

I

MPORTANT

S

AFETY

G

UIDELINES

SAVE THESE INSTRUCTIONS

NOTICE

Risk of overhead interference. Can cause module or structural damage.
The module may be too tall to fit through a doorway while on the skid. Measure the module

and doorway heights and verify clearances by referring to the installation plans and other

site-specific drawings and documents before moving the module.

Fluorinated Greenhouse Gas Requirements—European Union

Stationary air conditioning, refrigeration, heat pump equipments and stationary fire protection systems in

the European Community market and operating with fluorinated greenhouse gases (f-gas), such as R407C,

R134a, R410A, must comply with the F-Gas Regulation: (EC) No. 842/2006 (F-gas). The regulation prohibits,

among other actions, venting fluorinated greenhouse gases to the atmosphere.
The F-Gas Regulation also requires operators to use all measures that are technically feasible and do not

entail disproportionate cost to prevent leakage of these gases, to test for leakage regularly and to recover f-gas

during equipment service and maintenance and before disposing of equipment.
Refer to the full regulation for additional details.

!

WARNING

Risk of top-heavy module falling over. Can cause equipment damage, personal injury or

death.
Improper handling can cause equipment damage, injury, or death. Read all of the following

instructions before attempting to move, lift, remove packaging from the module, or preparing

module for installation.

!

WARNING

Risk of explosive discharge of high-pressure refrigerant. Can cause personal injury or death.
This module contains fluids and/or gases under high pressure. Relieve system pressure before

cutting into or disconnecting piping or piping components.

!

WARNING

Risk of piping and component rupture. May cause equipment damage, personal injury or

death.
Closing service valves may isolate liquid refrigerant, causing high pressure and rupture of

piping. Do not close valves without following recommended procedures for repair,

maintenance and replacement of components. Install pressure relief valves in field piping

that may become isolated by service valves.

!

CAUTION

Risk of sharp edges, splinters and exposed fasteners. Can cause personal injury.
Only properly trained personnel wearing appropriate safety headgear, gloves, shoes and

glasses should attempt to move, lift, remove packaging from, or prepare module for

installation.

!

CAUTION

Risk of improper operation and overpressurization. Can cause in personal injury or property

damage.
Only personnel properly trained and qualified in HVAC installation or service should install

or service this equipment.
Read all installation, operating and safety instructions before proceeding.