888-60-182P-01 rev.D • 01/07

17 of 22

7
a

Hold Rail against wall and start

screws with washers.

b

Tighten screws with 13mm socket

head (power tool is recommended)
in the following sequence: 1st-lower
right; 2nd-upper left; 3rd-lower left;
4th-upper right.

DO NOT OVERTIGHTEN SCREWS!

For solid concrete applications, torque

screws to 60 in-lbs (6.8 N m).

Screws must be fully seated in order to

support applied load!

The minimum torque for screws in

solid wood studs is 60 in-lbs minimum
(6.8 N m)while the maximum torque is

82 in-lbs (9.3 N m).

7