Voltage signal, Wire voltage transducer signal, P+ p – Precision Digital PD603 User Manual

Page 13

Advertising
background image

Sabre P Model PD603 Process Meter

Instruction Manual

13

SIGNAL CONNECTOR

2

1

3

5

4

Voltage

Signal

+

-

COM

mA+

V+

X

X

COM

SIGNAL CONNECTOR

mA+

2

1

3

5

4

V+

X

X

3-Wire

Voltage

Transducer

Signal

+

2

1

24V OUT

-

P+

P-

Figure 6. Voltage Input Connections

The meter is capable of accepting any voltage from -10 VDC to +10 VDC.