To select am modulation, To select carrier waveform shape, To set carrier frequency – RIGOL DG4000 Series User Manual

Page 102: Am -2, To select am modulation -2

Advertising
background image

RIGOL Chapter 5 Modulated Waveform Output

DG4000 Series User’s Guide

5-2

AM


Modulated waveform usually consists of carrier waveform and modulating
waveform. For amplitude modulation (AM), the amplitude of the carrier waveform
varies with the instantaneous voltage of the modulating waveform.

To Select AM Modulation


Press ModTypeAM to enable AM function.
 When Mod is enabled, Sweep or Burst will be disabled automatically (if

enabled currently).

 After AM is enabled, the instrument will generate AM waveform with the

currently specified carrier and modulating waveforms.


To Select Carrier Waveform Shape


AM carrier waveform could be Sine, Square, Ramp or Arbitrary waveform (except
DC). The default is Sine.
 Press the front panel key Sine, Square, Ramp or ArbSelect Wform (or

User, the pre-defined waveform can not be DC) to select a desired carrier

waveform shape.

 Pulse, Noise and DC could not be used as carrier waveform.

To Set Carrier Frequency


Different carrier waveforms have different frequency ranges as shown in the table
below. For all the carrier waveforms, the default value is 1kHz.

Carrier Waveform

Frequency Range

Sine

1μHz to 160MHz

Square

1μHz to 50MHz

Ramp

1μHz to 4MHz

Arbitrary Waveform

1μHz to 40MHz

Advertising