Chapter 2 Basic Waveform Output

RIGOL

DG4000 Series User’s Guide

2-15

Delay

Delay is defined as the delayed time of the output of a channel relative to the
output of the other channel. The range of delay is from 0s to pulse period and the
default is 0s.

Delay

CH1 Output

CH2 Output


Press Delay to highlight the softkey. Use the numeric keyboard or direction keys
and knob to input the desired value and select the desired unit from the pop-up
menu.
 For the input method of the value, refer to the introduction in Parameter

Setting Method.

 Selectable Delay Time units: sec, msec, μsec, nsec.

Recover Delay


Press Pulse, then use

to open the 2/2 menu page and press Restore, the

generator will align the delay between the two channels. Assume that CH1 and CH2
output pulse waveforms with the same parameters. Use the oscilloscope to sample
the waveforms of the two channels and display them stably. Then, toggle the output
switch of the generator. The two waveforms displayed on the oscilloscope have a
certain delay. At this point, press Restore on the generator and the waveforms will
be displayed on the oscilloscope without any delay.