Type 1 format (arnav format), Control inputs – Rosen Aviation 0604 Series : Rosenview VX User Manual

Page 16

Advertising
background image

Rosen Aviation

RosenView VX Technical Manual

Document Number: 100640

Revision: G
Date: 9/19/12

Template: 4.4.1.6FM1; Revision A; 31 May, 2012

Page 16 of 23

4.3.2. Type 1 Format (ARNAV format)

The Type 1 output sentences shall have the following general format:

Id

item designator (single ASCII alphabetic character)

Dddd

item data (1 to 10 printable ASCII characters)

CR

ASCII carriage return character (0D hex)

LF

ASCII line feed character (0A hex)

4.3.3. Shadin Formats (Altitude Sentence, Airdata Z, Airdata G, Airdata S)

Only Shadin S format has most of the data required to run the RosenView VX. Formats Z
and G do not have positional information, and none of the Shadin formats have
destination information.

4.4. Control Inputs

For controller information, access

www.rosenaviation.com

.

Click on the Products tab, and then select AccessoriesExt.
Controllers
. Scroll down to view the RosenView external
controllers.

The RosenView VX IR receiver uses NEC-style 32-bit encoding. In this encoding format, there
are 16 bits of actual information transmitted as part of a 32-bit frame. The 16 bits of information
are divided into two parts: an 8-bit device code and an 8-bit function code.

Each 8-bit portion of the transmitted code is followed by the same code with each bit inverted.
Most IR remotes using this format will have the same device code for each button on the remote,
and a unique function code for each button.

Listed below are the default codes in hexadecimal format used with RosenView VX:

Table 6 Default codes used with the RosenView VX

Control

Device Code

Function Code

Enter Button:

0xE7

0x0D

Pan Up:

0xE7

0x08

Pan Down:

0xE7

0x09

Pan Left:

0xE7

0x11

Pan Right:

0xE7

0x10

Zoom In:

0xE7

0x52

Zoom Out:

0xE7

0x40

Advertising